STEP 7-Micro/WIN 16 Version 2.11
STEP 7-Micro/WIN 32 Version 2.12

Copyright (c) Siemens Energy & Automation Inc., 1998

--------------- INSTALLATION ---------------
Close all applications including the MS-Office Toolbar before installing STEP 7-Micro/WIN. Other applications that use the same set of system files must be closed in order for STEP 7-Micro/WIN to install properly.

System Requirements:

* Recommended Processor & Memory: a personal computer (PC) with an 80586 or greater processor and 16 Mbytes of RAM, or a Siemens programming device (such as a PG 740)
* Minimum Processor & Memory: 80486 processor with 8 Mbytes of RAM
* Microsoft Windows 3.1, Windows for Workgroups 3.11, Windows 95, or Windows NT 4.0
* At least 50 Mbytes of free hard disk space
* VGA monitor, or any monitor supported by Microsoft Windows
* Optional but recommended: any mouse supported by Microsoft Windows
* One of the following sets of equipment:
     - A PC/PPI cable connected to your communications port (PC COM1 or COM2)
     - A communications processor (CP) card and multipoint interface (MPI) cable
     - A multipoint interface (MPI) card (A communications cable comes with the MPI card.)


Installation Instructions:

(Windows 95, Windows NT 4.0)
1. Insert STEP 7-Micro/WIN Diskette 1 in Drive A or B.
2. Click on the Start button and select Run.
3. Type A:\setup or B:\setup (according to the drive you selected in Step 1).
4. Click on the OK button.
5. Follow the instructions displayed to complete the installation.

(Windows 3.1, Windows 3.11, Windows NT 3.51)
1. Insert STEP 7-Micro/WIN Diskette 1 in Drive A or B.
2. Select File->Run from the Program Manager.
3. Type A:\setup or B:\setup (according to the drive you selected in Step 1).
4. Click on the OK button.
5. Follow the instructions displayed to complete the installation.


--------------- WHAT'S NEW IN VERSION 2.1 ---------------

*  Undo feature

*  Ladder Instruction Bar

*  Instruction Wizards
     - NETR/NETW Wizard
     - Analog Input Filter Wizard
     - PID Wizard
     - High Speed Counter Wizard

*  Modem Support

*  New Communications Hardware and Protocol Support (STEP 7-Micro/WIN 32)

*  Integration into STEP 7 SIMATIC Manager (STEP 7-Micro/WIN 32)
     Notice: STEP 7-Micro/WIN 32 will only work with STEP 7 v4.02 or 
             greater as an integrated product.


---------------- UPDATES INCLUDED IN VERSION 2.11 ----------------

STEP 7-Micro/WIN v2.11 corrects some minor problems found in STEP 7-Micro/WIN v2.1. There are two ways to obtain v2.11.
*  You may have received v2.11 on diskettes when you purchased STEP 7-Micro/WIN.
*  You can upgrade to v2.11 from v2.1 by installing Service Pack 1 (available via the Internet or from your local Siemens supplier).

The problems fixed by v2.11 (or Service Pack 1) include:

*  Page Setup - if you delete the header or footer with Page Setup, and then you save the project, the project cannot be reopened.

*  STL & DB Editing - only applies to STEP 7-Micro/WIN32. If you have a large program and you are making edits near the top of the program, the response to the keyboard is visibly slower. This problem is not as noticeable in smaller programs, or in the middle of larger programs.

*  Uninstall - if you update from STEP 7-Micro/WIN16 V2.0 to STEP 7-Micro/WIN16 V2.1, and you install the new software into the same directory as the existing software, you will remove both versions of the software whenever you try to uninstall V2.0.

*  Print Preview - large amounts of program documentation can cause Print Preview (and Print) to operate incorrectly.

*  Print Ladder - symbols and absolute addresses can be overlapped on the printout.


--------------- KNOWN PROBLEMS & REMEDIES --------------

1. If you open a STEP 7-Micro/DOS project (*.VPU), do not use the same filename for the STEP 7-Micro/WIN project. STEP 7-Micro/WIN will overwrite the STEP 7-Micro/DOS comment file.

2. If you experience problems printing with an HP 660Cse color printer, change the printer driver to the basic HP Deskjet printer driver to correct the problem. If you are experiencing problems with other printers, try using a different printer driver.

3. If you are using STEP 7-Micro/WIN on a Siemens PG 740 programming device and experience communications problems with the CPU, newer communication drivers are required. These newer drivers are provided on STEP 7-Micro/WIN diskettes. To correct the problem, copy the newer drivers (COMM.DRV and SERIAL.386) from Disk 4 into your Windows\System directory.

4. When running Windows 3.1 or 3.11, ensure that you are running in Enhanced mode for proper operation.

5. Previous versions of STEP 7-Micro/WIN would allow certain ladder constructs to be created that are no longer supported in the ladder view. If you see "Illegal" for the network number, you have encountered a situation where the statement list code can not be converted to its ladder equivalent. You must go to the Statement List view and edit your code before the network can be represented in ladder.



---------------- UPDATES INCLUDED IN VERSION 2.12 ----------------

STEP 7-Micro/WIN32 v2.12 corrects some installation problems that result in STEP7-Micro/WIN32 overwriting some
existing STEP7 device drivers whenever STEP7-Micro/WIN32 is installed after STEP7 
has been installed. This problem is not present in STEP7-Micro/WIN16 because 
different device drivers are used. There are no new features added with this release.

There are two ways to obtain v2.12.
*  You may have received v2.12 on diskettes when you purchased STEP 7-Micro/WIN.
*  You can upgrade to v2.12 from v2.1 or V2.11 by downloading and installing Service Pack 2 (available via the Internet or from your local Siemens supplier).


--------------- KNOWN PROBLEMS & REMEDIES --------------
1. Installation with STEP7: If you install STEP7-Micro/WIN32 after you
   have installed STEP7, STEP7-Micro/WIN32 now checks the date of the
   existing STEP7 drivers to make sure they are not accidentally replaced
   with older versions of the drivers. 



--------------- NATIONAL LANGUAGES ---------------

STEP 7-Micro/WIN uses several Microsoft common dialog boxes.  The text in these dialogs will appear in the national language of the operating system, regardless of the language you have chosen for STEP 7-Micro/WIN.



--------------- GENERAL COMMUNICATIONS ---------------

NOTE : All of the following information is explained in detail in the S7-200 Programmable Controller System Manual.


   CPU Type        Version       Hardware Supported      Baud Rates    OS           Communications Support
   -------------------------------------------------------------------------------------------------------
   212, 214, 216   Micro/WIN 16  PC/PPI Cable             9.6 kbaud  Windows 3.x     PPI
   215 (port 0)                  MPI-ISA Card            19.2 kbaud                  PPI Multi-Master

   212, 214, 216   Micro/WIN 16  PC/PPI Cable             9.6 kbaud  Windows 95      PPI
   215 (port 0)                  MPI-ISA Card            19.2 kbaud

   212, 214, 216   Micro/WIN 32  PC/PPI Cable             9.6 kbaud  Windows 95      PPI
   215 (port 0)                  MPI-ISA Card            19.2 kbaud  Windows NT 4.0  PPI Multi-Master
                                 MPI-ISA Card on Board
                                 CP5411, CP5511, CP 5611

   215 (DP port)   Micro/WIN 32  PC/PPI Cable             9.6 kbaud- Windows 95      MPI
                                 MPI-ISA Card              12 Mbaud  Windows NT 4.0
                                 MPI-ISA Card on Board
                                 CP5411, CP5511, CP 5611
   --------------------------------------------------------------------------------------------------------
    Note : STEP 7-Micro/WIN 16 does NOT support the CPU 215 (DP port)



------- MULTI-MASTER COMMUNICATIONS -----

Special Note:
     When using Multi-Master communications on networks with several masters (including TDs, OPs, etc.), the hardware takes several seconds to be initialized onto the PLC network. If communication is attempted before this initialization is complete, an error may occur. If such an error does occur, retrying the last request should correct it.


Setting STEP 7-Micro/WIN Network Addresses:
     As a general rule, use the lowest available addresses for masters and the higher addresses for slaves. It is preferable, but not required, to use consecutive addresses for the masters on a network. For example, a network with STEP 7-Micro/WIN, a TD 200, an OP15, and some number of S7-200s could use address 0 for STEP 7-Micro/WIN, 1 for a TD 200, and 2 for an OP15. The S7-200s could then be addressed as 3, 4, and 5, or you could leave these numbers free for additional masters and start the numbering of the S7-200s at 16.


TD 200/MPI:
     There exists a possible problem when downloading or uploading a program with the CPU 215 or CPU 216 when an older TD 200 (pre-v1.2) is polling the CPU. The current time-out error on the TD 200 is no longer appropriate for these newer CPU models. A workaround is to temporarily disconnect the TD 200 from the network, download or upload the program, and then reconnect the TD 200 to the network.


Master Mode Communications Error:

     STEP 7-Micro/WIN might report erroneous communications time-out errors when the PLC is in Master mode. For example, using STEP 7-Micro/WIN to put the CPU in STOP mode might return this error even though the CPU did in fact go to STOP mode.  


There may be a problem when using Multi-master communications with a PC/PPI cable on a 386 or 486 computer with Windows 95.  The Find function will work but no other communication function will work correctly.  The problem may be corrected by enabling the 16550 UART setting and adjusting the receiver FIFO level to the lowest setting for the COM port.  This is done with the Windows Device Manager.

------- PPI COMMUNICATIONS -------

Using PPI Multi-Master Configuration: 
     When Multi-Master is checked on the PPI Network tab and STEP 7-Micro/WIN is communicating through COM1 or COM2, if you start another application which uses the same COM port as STEP 7-Micro/WIN, neither application will operate correctly. If this occurs, close both applications, then restart only one.

--------------- MPI COMMUNICATIONS ---------------

Setting up the MPI Cards with STEP 7-Micro/WIN:

     In order to communicate using the MPI card, the STEP 7-Micro/WIN MPI driver requires that the memory space used by the card be reserved (excluded) by the system. This prevents the memory manager from allocating this area of memory to another application. SIMATIC STEP 7 does not require this memory to be excluded, but should operate properly with the memory either included or excluded.

     The memory space used by the MPI card is selected by using the switches on the card. The default address space on the MPI card is 0xDC000-0xDC407 on a PC, which is the recommended address space.  On a PG, the default is 0xCC000-0xCC407. The procedure for excluding this memory depends upon the memory manager in use.  

     Example cases for setting up the MPI card parameters are given below. Be sure to back up your CONFIG.SYS file before making any changes.

  MPI Cards for STEP 7-Micro/WIN 16 using Windows 3.x, Windows 95, Windows NT
  ---------------------------------------------------------------------------

  - Case 1:  MPI Card on a PG or PC running Windows 3.x or Windows 95.

       1. In the CONFIG.SYS file, look for a line of code similar to the following that loads the memory manager: DEVICE=EMM386.EXE X=E000-EFFF
       2. Add the new parameter X=DC00-DCFF and save the file.
       3. The end result should look as follows: DEVICE=EMM386.EXE  X=DC00-DCFF  X=E000-EFFF

       Please note that this configuration example assumes that the MPI card is at address 0xDC00, which is the default for the PC ISA card. If the settings are different, then the address range to be excluded should be changed to match the card.

   - Case 2:  MPI Card on a PG or PC running Windows 95.

       1. In the CONFIG.SYS file, look for a line of code similar to the following that loads the memory manager: DEVICE=EMM386.EXE   X=A000-BFFF  I=C000-CCFF  I=CD00-DFFF  X=E000-EFFF  FRAME=D000
       2. Change the I=C000-CCFF to X=C000-CCFF and save the file.
       3. The end result should look as follows: DEVICE=EMM386.EXE X=A000-BFFF  X=C000-CCFF  I=CD00-DFFF  X=E000-EFFF  FRAME=D000

       Please note that this configuration example assumes that the MPI card is at address 0xCC00, which is the default for a PG. If the settings are different, then the address range to be excluded should be changed to match the card.


  MPI Cards for STEP 7-Micro/WIN 32 using Windows 95
  --------------------------------------------------

  - Case 1: CP5511, CP5611 
     These cards are Plug-and-Play; they are automatically detected and self-initializing.

  - Case 2: CP5411, MPI-ISA Card, MPI-ISA Card on Board
     These cards are installed from the communications setup. The address ranges and interrupt are detected by Windows 95 and set up automatically.


  MPI Cards for STEP 7-Micro/WIN 32 using Windows NT
  --------------------------------------------------

  - Case 1: CP5511, CP5611
     These cards are automatically detected and self-initializing.

  - Case 2: CP5411, MPI-ISA Card, MPI-ISA Card on Board
     These cards are installed from the communications setup. It is necessary to specify the resources (addresses space and interrupt) used by the card from the communications setup.